Bioptechs FCS3

Bioptechs FCS3

The FCS3® System is an environmental chamber used on a microscope to enable the acquisition of high resolution, time-lapse images of cells undergoing either natural growth or fluidic exposure to variant factors.  The FCS3® provides the same capabilities on an upright microscope as the FCS2® System does for inverted microscopes.  Both systems enable the user to define precise and unlimited flow characteristics within the chamber to suit their protocols.  Bioptechs’ patented thermal design provides uniform temperature control across the entire field.  This is a feature that is not possible with a peripheral only heated chamber.

281-579-0342

Call today to see if a Bioptechs product is right for you.

Bioptechs FCS3
The Focht Chamber System 3 (FCS3 ®) is a closed system, live-cell micro-observation flowcell chamber that offers several advantages over other chambers. In addition to its unique perfusion and thermal control system, it is fully compatible with all modes of microscopy. It is also the only chamber to combine high-volume laminar flow perfusion rates with Koehler illumination and precise temperature control without an air curtain. Its user definable flow characteristics make it adaptable to nearly any protocol where cells are perfused in a flow-cell.

Why do you need an FCS3?
The FCS3 is a flow cell or flow chamber that is designed specifically for the demands of today’s live-cell imaging requirements. It has limitless flow characteristics because its flow geometry can easily be customized by the user. It can provide low shear near laminar flow as well as high shear in a directed flow and anything in between. The most important feature of the FCS3, other than unequalled temperature uniformity, is that there is a precise directed flow of media over the cells. Open dish type chambers do not provide the flow capabilities of the FCS3. The FCS3 provides an optical imaging cavity where the user can precisely define the optimum flow characteristics necessary for the experiment.FCS3 users enjoy the following characteristics:

  • Easy no tools needed assembly
  • Compatibility with all modes of microscopy
  • Complete control of the volume within the optical cavity
  • Complete control of the separation between optical surfaces
  • Complete control of the shape or profile of the flow channel
  • Complete control of the temperature uniformly across the entire field
  • Compatable with upright microscopes

How does it work?
Cells are grown on a 40mm glass coverslip. This coverslip is then incorporated into a perfusable fluid optical cavity that is compatible with all modes of microscopy, and its geometry can be easily defined by the user. This optical cavity is secured into a fixture on the stage of the microscope where media can be perfused or remain static.
When media enters the chamber, it is prewarmed, then emerges into a fluid optical path where the media is precisely directed over the cells. The media is collected within the optical cavity and directed out of the chamber on the other side. The flow characteristics of the media in the optical cavity are easily modified by selecting gaskets of varying geometry that direct the flow. Temperature control is maintained by both peripheral thermal support from the chamber metal frame and heat that is emitted from an electrically conductive optically transparent coating on the Microaqueduct “window” of the optical cavity. This technique provides uniform temperature control across the entire field, thus eliminating the temperature gradient that occurs with other designs. This technique also enables the FCS3 to recover from perfusion induced temperature fluctuations in just seconds.

Temperature Control:
The FCS3 was designed to maintain accurate thermal control and allow high-volume laminar flow perfusion. Both of these functions are incorporated into our patented Microaqueduct Slide (see drawing below). The surface of the Microaqueduct Slide, opposite the specimen side, is coated with an electrically conductive, transparent, thin film of Indium-Tin Oxide (ITO), and two electrical contacts (busbars). When the FCS3 is completely assembled two electrical contacts, (not shown in drawing), which are contained in the electrical enclosure rest on the busbars. A temperature controller is used to pass a regulated current through the ITO Coating. This causes the surface of the slide to heat. The heat is transferred through the media to the cell surface on the coverslip thereby providing direct thermal control. The self locking base of the chamber is also temperature regulated to provide peripheral heat as well.
Thermographic Images:

Visible Light Image of a Bioptechs FCS2
Visible Light Image of a Bioptechs FCS2
Visible Light Image of a Bioptechs FCS2
Visible Light Image of a Bioptechs FCS2

The thermograph above demonstrates the uniform temperature distribution of an FCS3. Notice that the coverslip temperature is so uniform that its location, in infrared, is indistinguishable from the base of the chamber. This demonstrates the effectiveness of the ITO heated Microaqueduct Slide. It is capable of re-equilibrating cell temperature within seconds of perfusion and eliminates the typical thermal gradient that occurs with peripheral heating.

Microaqueduct Perfusion:
A fluid pathway is formed by separating the Microaqueduct Slide from the coverslip containing cells with a single silicone gasket. This gasket can be any thickness from 50 microns to 1mm and any lateral geometry you choose or create. This arrangement allows the user to define the flow characteristics within the optical cavity formed between the micro aqueduct slide and coverslip. Therefore, you are not limited by the geometry of the optical cavity. Instead you select or create it! Fluid access to this flow channel is made through two 14-gauge needle stock tubes protruding from the sides of the chamber base These tubes provide fluid connection to two perfusion holes in the Microaqueduct Slide that interface two “T” shaped grooves cut into the inner surface of the Microaqueduct Slide. The “T” groove allows the media to seek the path of least resistance and become nearly laminar before flowing across the cells. This technique eliminates the need for the metal perfusion ring and additional gaskets, which are the limiting factors, required by most conventional chambers. (see drawing below)

microaquflo

Isometric View of Optical Cavity Microaqueduct Slide is transparent glass but rendered as a solid to improve contrast to illustrate function
Isometric View of Optical Cavity
Microaqueduct Slide is transparent glass but rendered as a solid to improve contrast to illustrate function

Microaqueduct design enables proper Koehler illumination with high-numeric aperture optics for both transmitted and reflected modes of microscopy.

  • Suitable for static or high rate flow applications where a rapid exchange of media is required with low cell surface shear
  • Cell temperature can be controlled from ambient to 50 degrees C +/- 0.2 degrees C without the need of an air curtain
  • Temperature is controlled uniformly across entire field with media equilibrating as it enters the chamber
  • Closed system so that bicarbonate CO2 or organic buffers can be employed
  • Compatible with 1/16″ tubing for perfusion (C-Flex, Tygon, etc.)
  • Easily assembled with ordinary skill (no tools required)
  • Stand-alone temperature controller with an alarm circuit to safeguard your cells
  • Near laminar flow
FCS3 Exploded View
FCS3 Exploded View
  1. FCS3 Top
  2. FCS3 Pressure Plate
    Designed to assure parallel uniform closure, eliminate leaks, & broken coverslips
  3. 40mm coverslip
    Surface where your cells are grown
  4. Singular lower gasket
    This gasket can have any internal geometry you desire
    Standard thicknesses from .1mm to 1mm
    Allows you to define the volume and flow characteristics of the chamber
  5. Microaqueduct Slide
    An optical surface which integrates perfusion and temperature control
    High-volume laminar flow
    Koehler Illumination
    Electronically conductive coating for temperature control
  6. Upper Gasket
    Provides a seal between the FCS3 base and Microaqueduct slide
  7. Perfusion Tubes (14 gauge) (CO2 Perfusion Drawing)
  8. FCS3 base
    Temperature controlled
    Dovetail to lock into stage adapter for stability
    No tools required for assembly

Singular lower gasket
By simply changing this one gasket you can change the volume of the chamber. This gasket can have any internal geometry you desire and can be any thickness from 0.1mm to 1mm. The drawing below shows the standard shapes of the gaskets that we include with every FCS3. We also include solid gaskets for you to custom fit to your application. Once you have found the shape that works best for your experiment you can contact us to have a die made to those specifications. Examples of standard gasket outlines (below)
stdgasketset

Standard Gasket Set includes:
(3) 0.1mm Thick 30mm Round
(2) 0.1mm Thick 14 x 24 Rectangle
(3) 0.25mm Thick 30 mm Round
(2) 0.25mm Thick 14 x 24 Rectangle
(1) 0.25mm Thick Blank
(3) 0.5mm Thick 30mm Round
(2) 0.5mm Thick 14 x 24 Rectangle (2) 0.5mm Thick Blank
(5) 0.75mm Thick 30mm Round w/holes
(2) 0.75mm Thick 14 x 24 Rectangle
(1) 0.75mm Thick Blank
(2) 1.0mm Thick 30mm Round
(1) 1.0mm Thick 14 x 24 Rectangle
(1) 1.0mm Thick Blank

To order a specific geometry please see the price list for part numbers and prices. Gaskets are sold 5 gaskets per pack.

In addition to the standard gasket set that comes with the FCS3 Starter Kit, shown above, there are a variety of gasket geometries, and thicknesses ranging from 0.1mm to 1mm available. See the additional gaskets shapes chart below.

Additional gasket shapes

Custom shapes are available. Simply contact Bioptechs to make arrangements for their production. All dimensions below are in millimeters. Please specify the die number that is located on the gasket drawing below and the thickness of the gasket when ordering.
FCS_Gaskets

Perfusion Diagram for FCS3

CO2 Enriched Media Schematic for Bioptechs FCS2 & FCS3 systems. Easy to setup, reliable and consumes very little CO2
CO2 Enriched Media Schematic for Bioptechs FCS2 & FCS3 systems. Easy to setup, reliable and consumes very little CO2.
Meyer Instruments, Inc., is an authorized Bioptechs Dealer Reseller
How can we help? Call us: +1 (281) 579-0342 or 281-755-4332
Got a question? Need a quote? Want a demo or trial? Email to rdm@meyerinst.com or fill out the form below and we will be in contact shortly.

    Your Full Name (required)

    Telephone Number

    Your Email (required)

    What can we help you with?

    Can you be more specific?